Short answer

Published ranges put leak repair at about $200 to $1,500, an R-410A recharge at about $100 to $320, and an R-22 recharge at about $180 to $600. An expansion valve (TXV) runs about $200 to $600 and an evaporator coil $1,000 to $4,500. A recharge without finding the leak is only a temporary fix.

HVAC technician nitrogen-purging and torch-brazing copper refrigerant line set connections Technical Consideration
Electronic leak detectors and nitrogen pressure testing locate pinhole evaporator leaks.

Typical refrigerant-related repair costs

Typical refrigerant-related repair costs
RepairTypical range
Refrigerant recharge (R-410A)$100 – $320
Refrigerant recharge (R-22)$180 – $600
Leak search and repair$200 – $1,500
Expansion valve (TXV)$200 – $600
Evaporator coil replacement$1,000 – $4,500

Published U.S. ranges for planning only, not Wilmington quotes. Your written price depends on diagnosis, access, equipment, permits, and timing. Sources: HomeGuide – AC repair cost (Aug 2025); HVAC.com – heat pump repair costs.

Why is a leak check expensive?

Finding a leak can take hours with electronic detectors, dye, bubble tests, or nitrogen pressure testing, especially in coils hidden inside air handlers.

Ask what method will be used and whether the leak search price is separate from the repair.

Does low refrigerant always mean a leak?

Yes, in almost every case. Refrigerant is not used up like fuel.

The only exception is an undercharge from a previous installation or service. A system that needs refrigerant every season has a leak.

What changed with R-410A in 2026?

New residential systems made since January 1, 2025 use lower-GWP refrigerants such as R-454B or R-32. EPA’s 2026 final rule lets contractors keep installing R-410A equipment made before 2025 until existing supplies run out.

R-410A remains available for servicing existing systems, but its production is being phased down, which can raise recharge prices over time.

When does a leak mean replace instead of repair?

Consider replacement when the leak is in the evaporator coil of a 12- to 15-year-old system, when the system uses R-22, or when leaks keep returning.

Ask for both prices: coil replacement versus a new matched system.

Related services in Wilmington

Local verification resources

Before authorizing work, use the Delaware license lookup. For projects that may require approval, consult the City of Wilmington permit information or the authority serving the property.

Keep reading

About this guide

Wilmington Climate Pros Editorial Team — Guides are researched from manufacturer documentation, published cost data, Delaware program rules, and local building conditions. They are educational and do not replace an on-site diagnosis by a qualified, licensed provider.

Common questions

Clear answers before you call

Is $2,800 reasonable for a leak search, repair, and recharge?

It can be if it includes a coil or major component; for a simple accessible leak plus a recharge it is high compared with published ranges. Ask for an itemized quote and a second opinion.

Can I add refrigerant myself?

No. Handling refrigerant requires EPA Section 608 certification.

Is a TXV replacement a big job?

It involves recovering refrigerant, brazing, pulling a vacuum, and recharging, which is why labor is a large part of the cost.