Wilmington HVAC guide

Heat Pump Auxiliary Heat: Normal Behavior Versus a Problem

When heat pump auxiliary and emergency heat should run, when constant aux heat signals a problem, and the thermostat settings that fix it.

Exterior heat pump condenser undergoing automated hot-gas defrost cycle during cold Delaware winter day Defrost Cycle & Aux Heat
Short answer

Auxiliary heat normally runs during defrost, on very cold nights, and when you raise the thermostat several degrees at once. It should not run most of the day in mild weather. Constant aux heat usually points to thermostat configuration, a failed outdoor sensor, low refrigerant, or an undersized heat pump, and it can sharply raise electric bills.

Main residential electrical service panel showing dedicated 240-volt double-pole breaker installed for new heat pump Technical Consideration
Automated reverse-cycle defrost melts outdoor coil frost without prolonged auxiliary electric strip usage.

Aux heat: normal or not?

Aux heat: normal or not?
SituationNormal?
During a defrost cycle (a few minutes)Yes
After raising the setpoint 3+ degreesOften
Below the balance point on a cold nightYes
All day at 40°F outdoorsNo: request diagnosis
Emergency heat selected on thermostatNo: switch back to Heat

What is the difference between aux heat and emergency heat?

Aux heat supplements the heat pump automatically; emergency heat turns the heat pump off and uses backup heat only.

Emergency heat is for when the outdoor unit has failed, not for cold days.

Which thermostat settings matter?

Aux heat lockout temperature, compressor lockout, droop or differential, and adaptive recovery all control when strips turn on.

Smart thermostats installed without heat pump settings are a common cause of constant aux heat.

How do setbacks affect aux heat?

Large overnight setbacks force aux heat in the morning to catch up.

Smaller setbacks, or none, often cost less with a heat pump.

When is it a mechanical problem?

Low refrigerant, a stuck reversing valve, a failed defrost board, or an iced coil all reduce heat pump output and bring on aux heat.

If settings are right and aux still runs constantly, request diagnosis.

Related services in Wilmington

Local verification resources

Before authorizing work, use the Delaware license lookup. For projects that may require approval, consult the City of Wilmington permit information or the authority serving the property.

Keep reading

About this guide

Wilmington Climate Pros Editorial Team — Guides are researched from manufacturer documentation, published cost data, Delaware program rules, and local building conditions. They are educational and do not replace an on-site diagnosis by a qualified, licensed provider.

Common questions

Clear answers before you call

How much more does aux heat cost?

Electric resistance strips produce about one unit of heat per unit of electricity, while a heat pump often produces two to three, so heavy aux use can roughly double heating cost for those hours.

Can I disable aux heat?

Not entirely; it protects comfort and pipes during extreme cold and defrost. You can adjust the lockout temperature.

Ready to request help?

Tell us what your HVAC system is doing.

Call any time or send the service request form. For gas odor, smoke, fire, or a carbon-monoxide alarm, leave the property and contact emergency services or the utility first.

Call now: (302) 412-8942